Instructions:
1. Rinse the ampoule with the "standard" wording and the syringe with water ro and water Distilled and then carefully dry.
2. Use the supplied syringe, pour exactly 5ml of RO water into the ampoule "Standard", close the ampoule well with the cap and store it in the aquarium for 10 min In order for the water inside it reach the same temperature as the water contained
In the tub.
3. After 10 minutes Remove the standard ampoule from the aquarium and add 1 level of Standard iodine powder measuring measure 0.06 ppm. Rinse the ampoule with the cap e Shake up to completely dissolve the dust.
4. Using the supplied syringe, inject exactly 5 ml of water to be tested In the other ampoule (champion ampoule).
5. Add 5 drops of Iodine Pro Reagent A in standard and sample ampoules.
6. Add 8 drops of Pro Reagent B iodine in standard and sample ampoules.
7. Place both ampoules in the positions marked on the colored paper.
8. The standard ampoule acts as a timer for reaction. Compare water color in the standard ampoule looking from the top until the color of the water to its Interior reaches the color corresponding to 0.06 ppm of the colored paper. This is
The final point of the test, which will last about 5 -15 minutes for an aquarium at 25 ° C (77 ° F).
Use hot water to accelerate the reaction.
9. Once the test is finished, look at the champion from above and compare the color with those of the paper; Choose the iodine level that matches the more color similar. If necessary, estimate an average value.
10. The color in the champion ampoule will remain stable for 5 minutes. Don't consider the color In the ampoule sample this time lapse spent.