HQ + 75 GLD membrane
Reverse Osmosis System
The membranes characterized by the acronym HQ + (High Quality Plus) represent the latest generation of osmotic membranes that summarize all the technological innovations of recent years.
They are membranes equipped with a high rate of salts, they succeed, in fact, to hold up to 99% of dissolved salts. These values, until recently, were only achieved by the best industrial membranes with very high costs and with exercise pressures of 10 - 15 bar.
Furthermore, the particular composition of the membrane structure allows you to withdraw more osmotic water and to decrease the waste while maintaining a high quality of water. With normal membranes you can take from 15% to 20% of the water entering the membrane while 80% - 85% goes into scrap. The HQ + membranes instead allow to recover from 30% to 50% of total water.
Membrane Aquili HQ + 75 GLD
At 60 psi (~ 4 bar) 30% water recovery withholding salts 99%
At 60 psi (~ 4 bar) 40% water recovery withholding salts 98%
At 75 psi (~ 5 bar) water recovery 50% retained salts 97%
Tested membrane at 250 ppm = 390 microsiemens = 14 d ° kH of salts in solution.
25 ° temperature
PH 6.5 - 7.0
Each area of Europe has its own different water for organoleptic characteristics from all other waters.
To allow the correct use of our plants in each country of Europe, we have set them up with a safety report that goes from 1: 1.5 to 1: 2. This report, during use, settle automatically based on the input water pressure. (Standard membranes work with the ratio 1: 4)
In this way we sacrificed the maximum production peak reachable (in fact, you can reach 1: 1 ratio), but in every European country, to change the pressure or hardness of the water, the plant always has excellent performance and does not subject the membrane with excessive stress they can Do it collapse.
Warnings and precautions:
Do not use the water produced after inserting the new membrane. Throw the first 30 liters of water so as to eliminate traces of the harmful product in which the membrane is stored.
Do not use the water produced by the membrane to drink or food without being mineralized in order to bring the salts dissolved to the right levels.
The membranes have a limited resistance to contact with chlorine (hypochlorite). Continuous exposures cause irreversible damage.
It is recommended to change the prefilters in the osmosis plant at most every 6 months to ensure the efficiency and duration of the membrane for several years. It is also recommended to carry out monthly counterweights to prevent mineral fouling and have the maximum efficiency.
DAHQ