WaveReef Dosometrica pump 4 channels with digital adjustment [SD-04M ] Useful for the dosage of marine supplements, balling, or fertilization in fresh water aquarium
Prices valid only online
Authorized retailers
Vuoi essere avvisato se il prodotto tornerà disponibile?
Inserisci la tua mail di seguito, se sei registrato ti basterà premere il pulsante "Avvisami quando disponibile"
1. First display: Time - Minutes - Timer departure time
2. Second display: Pump No. - Quantity delivered, from 1 to 99 ml - Interval between each dosage, from 1 h to 7 days. Pump: button for pump selection Cal.: Calibration button F: button for manual feeding. At the start press and keep pressed to trigger the pump. + : plus - : minus Time: button to set time Calibration Press to enter Calibration mode. The display displays (01 50 10). Pump No. 1 begins the dosage. Check that the dosed liquid is 10 ml. If the dosed liquid is less than 10 ml, press <+> once and wait. Press again <+> until the exact dosage of 10 ml. If the dosed liquid is greater than 10 ml, press <-> once and wait. Press again <-> until the exact dosage of 10 ml. After calibrating Pump 1, press to switch to Pump 2, 3 and 4 and calibrate the same way. Finally, press and hold it down for 2 seconds to return to the main page showing the time. Manual or start-up unit: Press to trigger the pump and release the button to stop it. How to set the time: 1. Press